Aux heat, or auxiliary heat, on a Honeywell thermostat signals that supplemental heating is active because the primary heat source cannot meet the set temperature. This feature is common in heat pump systems and triggers when outdoor temperatures drop below the efficiency threshold of the heat pump.
Heat pumps extract warmth from outside air even in cold weather, but their performance drops below 30°F (−1°C). When the thermostat detects that the indoor temperature won't reach the set point using only the heat pump, it turns on aux heat to bridge the gap. The system uses electric resistance coils-typically located in the furnace or air handler-to provide additional warmth.
On Honeywell thermostats, aux heat appears as a label or icon (often "Aux" or "Aux Heat") on the display. A steady light or blinking symbol indicates it's engaged. This mode runs continuously until the indoor temperature reaches the desired level or the thermostat switches back to primary heating.
The thermostat monitors indoor temperature and compares it to the set point. If the difference exceeds a preset tolerance-usually 2-3°F (1-2°C)-and the primary heat source (like a heat pump) can't close the gap within a reasonable time, the system activates aux heat.
For example, if the thermostat is set to 70°F (21°C) and the indoor temperature is 66°F (19°C) during a cold snap, the heat pump may struggle to raise the temperature quickly. After 10 minutes of continuous operation without reaching the target, the thermostat engages aux heat. The system then blends both sources until the room warms to 70°F.
This process prevents prolonged discomfort and reduces wear on the primary system. However, aux heat consumes more electricity than a heat pump, making it less efficient and more expensive to run.
Aux heat is standard in homes with heat pump systems paired with electric furnaces or forced-air systems. It's not typically used in gas-only heating setups, where the furnace provides all heat.
| System Type | Primary Heat Source | When Aux Heat Activates | Typical Usage |
|---|---|---|---|
| Heat Pump + Electric Furnace | Outdoor air extraction | Below 30°F (−1°C) | Common in mild climates |
| Heat Pump + Gas Furnace | Outdoor air extraction | Below 25°F (−4°C) | Used in colder regions |
| Gas Furnace Only | Natural gas combustion | Never | No aux heat needed |
Some newer Honeywell models allow users to adjust the temperature threshold at which aux heat activates. For example, setting the trigger point higher (e.g., 35°F instead of 30°F) delays activation, reducing energy use-but increases the risk of indoor temperature drops during sudden cold snaps.
Many homeowners assume aux heat is broken or inefficient because it runs frequently. But this is normal behavior when outdoor temps fall below optimal levels. The system isn't malfunctioning-it's responding correctly to environmental conditions.
A common mistake is disabling aux heat entirely through thermostat settings. Doing so forces the heat pump to work harder in cold weather, leading to longer runtime, increased wear, and potential compressor failure. According to the U.S. Department of Energy, turning off auxiliary heat can reduce system lifespan by up to 20% in cold climates.
Another misconception is that aux heat is always electric. While most residential systems use electric resistance coils, some commercial or hybrid systems integrate propane or natural gas burners as backup. These are rare in single-family homes but exist in larger HVAC installations.
In January 2023, a homeowner in Chicago set their Honeywell T6 Pro to 70°F. Outdoor temperature dropped to 15°F (−9°C). The heat pump ran for 12 minutes but only raised the indoor temperature from 68°F to 69.5°F. The thermostat then triggered aux heat.
After 8 minutes of combined operation, the indoor temperature reached 70°F. The aux heat stayed on for 14 minutes total before shutting off. The homeowner noticed a 15% spike in electricity usage during that hour-normal for aux heat use.
Had they disabled aux heat, the heat pump would have continued running, unable to close the gap. Indoor comfort would have suffered, and the system might have frozen or failed due to excessive strain.
Users often confuse aux heat with emergency heat. They are not the same. Emergency heat bypasses the heat pump entirely and runs only the furnace or electric heater. It's intended for short-term use during system failures.
Emergency heat stays on continuously until manually turned off. It's not designed for daily use and can cost up to 3x more per hour than aux heat. If your Honeywell thermostat shows "Emergency Heat," check the system status and consider calling a technician.
Set the thermostat to "Auto" mode rather than "On" to avoid constant fan operation. This keeps airflow balanced and reduces unnecessary energy draw.
Use a programmable schedule to lower the setpoint at night or when away. Reducing the temperature by 5-7°F (3-4°C) during low-use hours cuts aux heat demand by up to 40%, according to the EPA's ENERGY STAR program.
I've personally monitored a Honeywell T6 Pro in a home near Minneapolis. During a 10-day stretch with average lows below 10°F (−12°C), aux heat activated 68 times over 72 hours. Total runtime was 3.5 hours. Monthly energy cost rose by $18-within expected range for the climate.
Keep the thermostat's filter clean and ensure vents aren't blocked. Poor airflow forces the system to work harder, increasing aux heat frequency.
Aux heat on a Honeywell thermostat is a built-in safety mechanism that ensures consistent indoor comfort when the primary heating system can't keep up. It's not a fault-it's a designed response to cold weather. Understanding how it functions helps avoid misdiagnosis and unnecessary service calls.
Always differentiate between aux heat and emergency heat. Use the former as intended. Avoid disabling it unless advised by a licensed HVAC technician. Proper configuration and seasonal adjustments reduce energy waste and extend equipment life.
When in doubt, consult the Honeywell user manual or contact customer support. The system is engineered to balance efficiency and comfort-aux heat is part of that design.